Datalogic-scanning POWERSCAN D8330 User Manual

Browse online or download User Manual for Accessories communication Datalogic-scanning POWERSCAN D8330. Datalogic Scanning POWERSCAN D8330 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 212
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
®
PowerScan D8330/M8300
Reference Manual
Australia
Datalogic Scanning Pty Ltd
North Ryde, Australia
Telephone: [61] (2) 9870 3200
Fax: [61] (2) 9878 8688
France and Benelux
Datalogic Scanning Sarl
LES ULIS Cedex, France
Telephone: [33].01.64.86.71.00
Fax: [33].01.64 46.72.44
Germany
Datalogic Scanning GmbH
Darmstadt, Germany
Telephone: 49 (0) 61 51/93 58-0
Fax: 49 (0) 61 51/93 58 58
Italy
Datalogic Scanning SpA
Vimercate (MI), Italy
Telephone: [39] (0) 39/62903.1
Fax: [39] (0) 39/6859496
Japan
Datalogic Scanning KK
Shinagawa, Tokyo, Japan
Telephone: 81 (0)3 3491 6761
Fax: 81 (0)3 3491 6656
Latin America
Datalogic Scanning, Inc
Miami, Florida, USA
Telephone: (305) 591-3222
Fax: (305) 591-3007
Spain and Portugal
Datalogic Scanning Sarl
Sucursal en España
Madrid, Spain
Telephone: 34 91 746 28 60
Fax: 34 91 742 35 33
United Kingdom
Datalogic Scanning LTD
Watford, England
Telephone: 44 (0) 1923 809500
Fax: 44 (0) 1923 809 505
www.scanning.datalogic.com
Datalogic Scanning, Inc.
959 Terry Street
Eugene, OR 97402
USA
Telephone: (541) 683-5700
Fax: (541) 345-7140
©2008 Datalogic Scanning, Inc.
90ACC1949 Rev. A
1/08
Page view 0
1 2 3 4 5 6 ... 211 212

Summary of Contents

Page 1 - Reference Manual

®PowerScan D8330/M8300Reference ManualAustraliaDatalogic Scanning Pty LtdNorth Ryde, AustraliaTelephone: [61] (2) 9870 3200Fax: [61] (2) 9878 8688Fra

Page 2

POWERSCAN® D8330/M8300 2 2 INSTALLATION CAUTION Connections should always be made with power OFF! 2.1 POWERSCAN® D8330 INTERFACE CABLE CONNE

Page 3 - CONTENTS

92 CODE SELECTION ~ AUTO-CONFIGURATION ~ ~ EAN/UPC FAMILY ~ ~ 2/5 FAMILY ~ ~ CODE 39 FAMILY ~ ~ CODE 128 FAMILY ~ ~ CODABAR FAMILY ~ ~ CODE 93 ~

Page 4

93 Code selections may be performed according to two different procedures: - Auto-configuration, allowing an automatic recognition and selection of

Page 5

Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 94 DISABLE ALL CODE FAMILIES ÌAZ0ÃÎ NOTE The reader allows up to

Page 6 - GENERAL VIEW

Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 95 EAN/UPC FAMILY disable the family ÌAA0MÎ c Read the desired fami

Page 7 - Figure D – C-8000

Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 96 WITH ADD ON 2 ONLY EAN 8/EAN 13 ÌAAK7Î UPC A/UPC E ÌAAM=Î

Page 8

Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 97 SELECT EAN/UPC PREFIXES NOTE When scanning the following codes, ba

Page 9 - 1 INTRODUCTION

Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 98 Example: The following string allows reading and transmitting wit

Page 10 - 2 INSTALLATION

Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 99 EAN/UPC CHECK DIGIT TX SELECTIONS For each code type in this family

Page 11 - CAUTION

Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 100 CONVERSION OPTIONS UPC E to UPC A conversion ÌAAAÄÎ UPC

Page 12

Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 101 2/5 FAMILY disable the family ÌAC0QÎ c Read the desired family

Page 13 - 2.4 USB

INSTALLATION 3 Follow the given procedure for correct cable insertion: c Slip the cover over the cable. d Push the plastic boot into the rubber

Page 14 - 2.5 IBM USB POS

Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 102 CODE 39 FAMILY disables the family ÌAB0OÎ c Read the desired

Page 15 - 2.6 WEDGE CONNECTION

Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 103 CODE 128 FAMILY disable the family ÌAI0]Î c Read the desired fam

Page 16 - 2.8 NETWORK CONNECTIONS

Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 104 CODE 93  disable the code ÌAK0aÎ Code 93 ÌAK1dÎ contro

Page 17 - 2.8.2 Network Cabling

Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 105 The Codabar ABC code below uses a fixed start/stop character trans

Page 18 - 2.8.3 Network Termination

Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 106 MSI  disable the family ÌAE0UÎ Enable the code by selecting on

Page 19 - M8300 Batteries

Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 107 CODE 11  disable the family ÌAG0YÎ Enable the code by selecting

Page 20

Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 108 CODE 16K  disable the code ÌAJ0_Î Code 16K ÌAJ1bÎ To read

Page 21 - 2.10.1 Desktop Mounting

Enter Configuration Exit and Save Configuration Ì$+;Î CODE SELECTION Ì$-?Î 109 GS1 DATABAR™ CODES  disable the family ÌAQ0mÎ DISABLE CODE dis

Page 22 - Fixed Desktop Use

110 ADVANCED FORMATTING NOT FOR PEN INTERFACES ~ CONCATENATION ~ ~ ADVANCED FORMATTING ~ NOTE Please follow the setup procedure carefull

Page 23

Enter Configuration Exit and Save Configuration Ì$+;Î ADVANCED FORMATTING Ì$-?Î 111 CONCATENATION  disable ÌEI0aÎ enable ÌEI1dÎ Permits t

Page 24 - 2.10.2 Wall Mounting

POWERSCAN® D8330/M8300 4 2.2 BC-80X0 INTERFACE CABLE CONNECTIONS BC-80X0 Connectors The BC-80X0 incorporates a multi-standard interface, which

Page 25 - Inclined Base Wall-mounting

Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 112 2 Code 2 code ID ÌEK1hÎ Read the code type from the Code Identifier Table beg

Page 26 - LAYOUTS

Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 113 5 Transmission after Timeout no code transmitted after timeout ÌEM0iÎ only c

Page 27

ADVANCED FORMATTING 114 ADVANCED FORMATTING Advanced formatting has been designed to offer you complete flexibility in changing the format o

Page 28 - 3.1.4 C-BOX Layout

Enter Configuration Exit and Save Configuration Ì$+;Î ADVANCED FORMATTING Ì$-?Î 115 1 Begin Format Definition begin Format 1 definition

Page 29 - 3.2.1 Host Master Layout

Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 116 4 Match with Predefined Characters no match ÌHD0HE00ÄÎ OR match with 1 c

Page 30 - 3.2.2 BC-8060 Master Layout

Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 117 5 Divide Code into Fields divide code into fields ÌHF.Î Read one number in t

Page 31 - /*32: FAIL*/

Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 118 DEFINE FIELD 1 BY: EITHER field separator a) ÌHG0`Î Read the field separator c

Page 32 - 4 CONFIGURATION

Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 119 DEFINE FIELD 2 BY: EITHER field separator a) ÌHG0`Î Read the field separator char

Page 33 - 4.2 SETUP PROCEDURES

Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 120 DEFINE FIELD 3 BY: EITHER field separator a) ÌHG0`Î Read the field separator ch

Page 34 - Ì$+$*oÎ

Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 121 DEFINE FIELD 4 BY: EITHER field separator a) ÌHG0`Î Read the field separator cha

Page 35 - ÌIB'Î

INSTALLATION 5 2.3 RS-232 CONNECTION 2.4 USB (if required)

Page 36 - Ì$+RN0$-IÎ

Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 122 DEFINE FIELD 5 BY: EITHER field separator a) ÌHG0`Î Read the field separator c

Page 37 - Ì$+RN1$-NÎ

Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 123 7 First Additional Fixed Field no fixed field ÌHI0dÎ 1 character fixed fi

Page 38 - END of procedure

Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 124 8 Second Additional Fixed Field no fixed field ÌHJ0fÎ 1 character fixed

Page 39 - M8300/STAR-SYSTEM™ SETUP

Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 125 9 Field Transmission number of fields to transmit ÌHK8Î Read one number in t

Page 40

Exit and Save Configuration ADVANCED FORMATTING Ì$-?Î 126 10 Standard Formatting do not apply standard formatting ÌHL0jÎ

Page 41 - Ì$+RF4Î

Enter Configuration Exit and Save Configuration Ì$+;Î ADVANCED FORMATTING Ì$-?Î 127 Enable Advanced Format  no Advanced Formats enabled ÌHN

Page 42 - Ì$+RZ1$-~Î

Enter Configuration Exit and Save Configuration Ì$+;Î ADVANCED FORMATTING Ì$-?Î 128 No Match Result clear data - no transmission ÌHO0pÎ tran

Page 43 - Ì$+CP6$-BÎ

129 RADIO PARAMETERS PowerScan® M8300 Series readers only ~ RADIO PROTOCOL TIMEOUT ~ ~ RADIO RX TIMEOUT ~ ~ POWER-OFF TIMEOUT ~ ~ TRANSMISSION

Page 44

Enter Configuration Exit and Save Configuration Ì$+;Î RADIO PARAMETERS Ì$-?Î 130 RADIO PROTOCOL TIMEOUT radio protocol timeout ÌRH<Î Re

Page 45

Enter Configuration Exit and Save Configuration Ì$+;Î RADIO PARAMETERS Ì$-?Î 131 POWER-OFF TIMEOUT power-off timeout ÌRPLÎ Read 2 numbers in

Page 46 - First Start-Up

POWERSCAN® D8330/M8300 6 2.5 IBM USB POS (if required)

Page 47

Enter Configuration Exit and Save Configuration Ì$+;Î RADIO PARAMETERS Ì$-?Î 132 BEEPER CONTROL FOR RADIO RESPONSE  normal ÌBF0XÎ only

Page 48

Enter Configuration Exit and Save Configuration Ì$+;Î RADIO PARAMETERS Ì$-?Î 133 SINGLE STORE  disable ÌRO0zÎ one attempt two attempts

Page 49 - RS-232 PARAMETERS

Enter Configuration Exit and Save Configuration Ì$+;Î RADIO PARAMETERS Ì$-?Î 134 BATCH MODE  disable batch enable normal batch ÌBZ0ÄÎ

Page 50

135 DISPLAY PARAMETERS PowerScan® M8300 Series readers only ~ DATE AND TIME ~ ~ CONTRAST ~ ~ FONT SIZE ~ ~ BACKLIGHT ~ ~ DISPLAY OFF TIMEOUT ~

Page 51 - ANDSHAKING

Enter Configuration Exit and Save Configuration Ì$+;Î DISPLAY PARAMETERS Ì$-?Î 136 DATE AND TIME set date ÌIA%Î set time Read 6 numb

Page 52

Enter Configuration Exit and Save Configuration Ì$+;Î DISPLAY PARAMETERS Ì$-?Î 137 DISPLAY-OFF TIMEOUT timeout ÌIF/Î Read 2 numbers in the rang

Page 53

Enter Configuration Exit and Save Configuration Ì$+;Î DISPLAY PARAMETERS Ì$-?Î 138 KEYPAD disable reader keypad ÌIK0iÎ  enable reader

Page 54 - USB PARAMETERS

REFERENCES 139 5 REFERENCES 5.1 RS-232 PARAMETERS 5.1.1 Handshaking Hardware handshaking: (RTS/CTS) The RTS line is activated by the decoder be

Page 55

POWERSCAN® D8330/M8300 140 5.1.2 ACK/NACK Protocol PowerScan® D8330 Readers This parameter sets a transmission protocol in which the Host respond

Page 56 - USB-COM

REFERENCES 141 BC-80X0 Host data cable PowerScan® M8300 data NACK ACK good RX beep Transmission Mode = Two-Ways data ACK/NACK enabled When ACK/

Page 57 - ATIONALITY

INSTALLATION 7 2.6 WEDGE CONNECTION 2.7 PEN EMULATION CONNECTION

Page 58 - USB-KBD

POWERSCAN® D8330/M8300 142 5.1.4 RX Timeout When the RS-232 interface is selected, the Host can be used to configure the device by sending it com

Page 59

REFERENCES 143 5.2.3 Overflow This parameter generates a white space before the first bar and after the last bar of the code. The selections are as

Page 60 - WEDGE PARAMETERS

POWERSCAN® D8330/M8300 144 5.2.5 Inter-Block Delay For the PEN Emulation interface, data are sent to the Host in fixed size blocks of 20 characte

Page 61

REFERENCES 145 The message is sent in the following format: "Message" CR LF 5.3.3 Reception Warning Message The Master cradle can trans

Page 62

POWERSCAN® D8330/M8300 146 These default values are always restored through the reading of RS-232 or WEDGE interface selection code, see chapter 2.

Page 63

Enter Configuration Ì$+;Î 147 5.4.2 Define Special Key Sequence The Special Key(s) for Wedge IBM AT-PS/2 and USB-KBD interface users can be a

Page 64

POWERSCAN® D8330/M8300 148 2. Read only one code to be associated with the special key sequence: SHIFT Ì12Î OR CTRL Ì23Î OR AL

Page 65

Exit and Save Configuration Ì$-?Î 149 3. Select the character to be associated with the Special Key sequence by reading the codes corresponding

Page 66 - MULATION

POWERSCAN® D8330/M8300 150 ITA USA FR BE DE UK ES SW JP : 049 S 04C S 049 049 049 S 04C S 049 S 049 S 052 ; 041 S 04C 041 041 041 S 04C 041

Page 67 - PEN EMULATION

REFERENCES 151 ITA USA FR BE DE UK ES SW JP w 01D 01D 01A 01A 01D 01D 01D 01D 01D x 022 022 022 022 022 022 022 022 022 y 035 035 035 035 01A

Page 68 - PERATING

POWERSCAN® D8330/M8300 8 2.8 NETWORK CONNECTIONS 2.8.1 BC-8060 Network Connectors The multidrop network is a bus system which is propagated fr

Page 69

POWERSCAN® D8330/M8300 152 ITA USA FR BE DE UK ES SW JP Up arrow 275 275 275 275 275 275 275 275 275 Down arrow 272 272 272 272 272 272 272 272 27

Page 70

REFERENCES 153 2. the following example allows defining Special Key 2 as CTRL + S (upper case): enter configuration define Special Key 2 CTRL +

Page 71

POWERSCAN® D8330/M8300 154 2. the following example allows setting Special Key 2 (defined in example 2 above) as header: enter configuration on

Page 72 - NETWORK PARAMETERS

REFERENCES 155 5.4.5 Time Stamping Format The Time Stamping parameter sets the format for hour and date information. It consists of 1 or 2 groups of

Page 73

POWERSCAN® D8330/M8300 156 5.5.2 Enter Sleep Timeout For readers that have the Sleep state enabled, this timeout determines when the reader will

Page 74

REFERENCES 157 When one read per cycle is selected, the device decodes only one code during the ON period and immediately turns the reader OFF. It is

Page 75

POWERSCAN® D8330/M8300 158 5.7.3 Interdigit Control The interdigit control parameter verifies the interdigit spacing for code families Code 39 a

Page 76 - ERMINATOR

REFERENCES 159 5.9.2 Radio RX Timeout When the scanner is used in a standalone layout (point-to-point or with multiple readers) it can be configured

Page 77 - DATA FORMAT

POWERSCAN® D8330/M8300 160 5.9.4 Transmission Mode This parameter determines whether the reader receives responses or messages from the Host or

Page 78

REFERENCES 161 5.9.6 Single Store When single store mode is enabled, if the PowerScan® M8300 fails to transmit a code to the cradle, it enters a sp

Page 79 - DENTIFIER

INSTALLATION 9 2.8.2 Network Cabling The Multidrop line is made using RJ45 connectors and a cable having the following specifications: • twisted p

Page 80

POWERSCAN® D8330/M8300 162 cannot be successfully completed, then the code is added to the list. When the reader returns in range, transmission of

Page 81

REFERENCES 163 5.10 DISPLAY PARAMETERS (SOME M8300 MODELS ONLY) 5.10.1 Display Mode The user can control the reader display behavior according to

Page 82

POWERSCAN® D8330/M8300 164 5.11 CONFIGURATION EDITING COMMANDS The following commands carry out their specific function and then exit the configu

Page 83 - DJUSTMENT

REFERENCES 165 5.12 CUSTOM DEFAULT CONFIGURATION Read the following code to set the reader user-defined configuration as custom default configuratio

Page 84

POWERSCAN® D8330/M8300 166 5.14 CONFIGURATION COPYING COMMANDS 5.14.1 Copy PowerScan™ D8330 Series Procedure: c Connect the master (correctly c

Page 85 - EPLACEMENT

REFERENCES 167 5.14.2 Copy PowerScan™ M8300 Series Procedure: c Using the slave reader and its BC-80X0 cradle, follow the initialization procedure i

Page 86

POWERSCAN® D8330/M8300 168 5.14.3 Copy BC-80X0 Procedure: c Using the slave reader and its BC-80X0 cradle, read the Restore Default barcode, set

Page 87

REFERENCES 169 5.15 DEFAULT PARAMETERS FOR POS TERMINALS The default values of the RS-232 and Data Format parameters for POS terminals are listed in

Page 88

POWERSCAN® D8330/M8300 170 5.16 FIRMWARE UPGRADE Device firmware upgrades can be performed using the Downloader utility tool (downloadable from t

Page 89 - POWER SAVE

MESSAGE FORMATTING 171 6 MESSAGE FORMATTING The system always provides scanner to host data communication using the following message formatting: O

Page 90

POWERSCAN® D8330/M8300 10 2.8.3 Network Termination The first and last cradles of the chain (the two ends of the bus) must be properly terminated

Page 91 - READING PARAMETERS

POWERSCAN® D8330/M8300 172 The general format for other asynchronous messages is: [Scanner_Addr] [Scanner_Addr_delimiter] [DC2] MESSAGE[CR]

Page 92

MESSAGE FORMATTING 173 • The cursor row position is not affected by the currently selected font. The display always has 4 rows, so when writing wit

Page 93

POWERSCAN® D8330/M8300 174 The LED control escape sequences are intended to activate the LEDs for short periods of time and can be used in combinat

Page 94 - NTENSITY

MESSAGE FORMATTING 175 The default characters associated with each key (KeyID) are shown in the following table: Default Key Identifiers Key KeyID ▲

Page 95

POWERSCAN® D8330/M8300 176 7 TECHNICAL FEATURES 7.1 POWERSCAN® D8330 Electrical Features PowerScan® D8330 PowerScan® D8330 AR Power Supply 4

Page 96

TECHNICAL FEATURES 177 7.2 POWERSCAN® M8300 Electrical and General Features Battery Type 2150 Li-Ion battery pack Recharge Time max. 4 hours with

Page 97 - DECODING PARAMETERS

POWERSCAN® D8330/M8300 178 7.3 BC-80X0 / C-8000 BC-80X0 C-8000 Electrical and General Features Supply Voltage External Power 10 to 30 VDC

Page 98

TECHNICAL FEATURES 179 7.4 SYSTEM AND RADIO FEATURES Radio Features European Models USA Models Radio Frequency 433.92 MHz 910 MHz Bit Rate 19200

Page 99

POWERSCAN® D8330/M8300 180 POWERSCAN® D8330/M8300 READER DATA ENTRY Beeper¹ LED Good Read Spot Meaning one beep² ON ON Correct read of a code in

Page 100 - CODE SELECTION

TECHNICAL FEATURES 181 BC-80X0/C-8000 POWER/COMMUNICATION Aux LED Host LED Yellow Yellow Meaning OFF OFF Device off ON Power applied through an e

Page 101 - CONFIGURATION

INSTALLATION 11 2.9 POWERSCAN® M8300 BATTERY MAINTENANCE 2.9.1 Battery Charging Once the system is connected and powered, you can place the Powe

Page 102

POWERSCAN® D8330/M8300 182 7.6 READING DIAGRAMS POWERSCAN® D8330/M8300 12 24 36 48 6096 36 24 12 012 24 36 cm 72 84108 cm 0.19 mm (7.5 mils) 0.25

Page 103

HOST CONFIGURATION STRINGS 183 A HOST CONFIGURATION STRINGS In this section we provide a description of how to modify the device configuration usin

Page 104

POWERSCAN® D8330/M8300 184 SERIAL CONFIGURATION STRINGS SPECIAL CONFIGURATION COMMANDS DESCRIPTION STRING Enter Configuration $+ Exit and Save Co

Page 105

HOST CONFIGURATION STRINGS 185 RS-232 DESCRIPTION STRING Baud Rate 300 CD1 600 CD2 1200 CD3 2400 CD4 4800 CD5 9600 CD6 19200 CD7 38400

Page 106

POWERSCAN® D8330/M8300 186 USB DESCRIPTION STRING USB-COM Handshaking disable CE0 RTS/CTS CE1 XON/XOFF CE2 RTS always ON CE3 ACK/NACK Prot

Page 107

HOST CONFIGURATION STRINGS 187 WEDGE DESCRIPTION STRING Keyboard Nationality Belgian FJ7 English (UK) FJ4 French FJ2 German FJ3 Italian FJ1 S

Page 108

POWERSCAN® D8330/M8300 188 PEN (continued) DESCRIPTION STRING Idle Level normal DE0 inverted DE1 Overflow narrow overflow DH0 medium overflow

Page 109

HOST CONFIGURATION STRINGS 189 DATA FORMAT NOT FOR PEN EMULATION INTERFACES DESCRIPTION STRING Code Identifier disable EB0 Datalogic standard EB1

Page 110

POWERSCAN® D8330/M8300 190 DATA FORMAT (continued) NOT FOR PEN EMULATION INTERFACES DESCRIPTION STRING Code Length Tx not transmitted EE0 trans

Page 111

HOST CONFIGURATION STRINGS 191 POWER SAVE DESCRIPTION STRING Sleep State disable BQ0 (only for D8330 series) enable BQ1 Enter Sleep Timeout (100 ms

Page 112

Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All righ

Page 113

POWERSCAN® D8330/M8300 12 2.10 MOUNTING THE BC-80X0 / C-8000 CRADLE The cradle package contains the following items: BC-80X0 / C-8000 Cradle BC

Page 114

POWERSCAN® D8330/M8300 192 DECODING PARAMETERS DESCRIPTION STRING Ink-spread disable AX0 enable AX1 Overflow Control disable AW1 enable AW0

Page 115

HOST CONFIGURATION STRINGS 193 CODE SELECTION (continued) DESCRIPTION STRING UPC A check digit transmission disable AAI0 enable AAI1 UPC E c

Page 116

POWERSCAN® D8330/M8300 194 CODE SELECTION (continued) DESCRIPTION STRING Codabar disable Codabar family AD0 Standard no start/stop character e

Page 117

HOST CONFIGURATION STRINGS 195 CODE SELECTION (continued) DESCRIPTION STRING Code 11 disable the family AG0 no check AG1 Type C with tx AG21

Page 118 - ADVANCED FORMATTING

POWERSCAN® D8330/M8300 196 DISPLAY PARAMETERS DESCRIPTION STRING Date IAddmmyy Time IBhhmm lighter IC0 Contrast darker IC1 small ID0 medium

Page 119 - ONCATENATION

CODE IDENTIFIER TABLE 197 B CODE IDENTIFIER TABLE 2/5 Interleaved ÌNOÎ 2/5 Industrial 2/5 normal 5 bars ÌPQÎ ÌOPÎ 2/5 matrix 3 bars EAN 8 ÌQRÎ ÌABÎ

Page 120

POWERSCAN® D8330/M8300 198 UPC A with 5 ADD ON ÌGHÎ UPC E with 2 ADD ON UPC E with 5 ADD ON ÌHIÎ ÌIJÎ Code 39 Code 39 Full ASCII ÌVWÎ ÌWXÎ CODABAR

Page 121

CODE IDENTIFIER TABLE 199 MSI ÌZ[Î Code 16K Code 11 ÌpqÎ ÌbcÎ Code 49 GS1 DATABAR Expanded Linear and Stacked ÌqrÎ ÌtuÎ GS1 DATABAR Limited GS1 DATABA

Page 122 - ORMATTING

C HEX AND NUMERIC TABLE CHARACTER TO HEX CONVERSION TABLE char hex char hex char hex NUL 00 * 2A U 55 SOH 01 + 2B V 56 STX 02 , 2C

Page 123

HEX AND NUMERIC TABLE HEX / NUMERIC TABLE CHARACTER TO HEX CONVERSION TABLE char hex char hex char hex € 80 ª AA Õ D5  81 « AB Ö D6 ‚ 82 ¬

Page 124

INSTALLATION 13 2.10.1 Desktop Mounting For desktop usage, you can mount the cradle either on the horizontal base, for reduced overall dimensions,

Page 125

HEX AND NUMERIC TABLE HEX / NUMERIC TABLE CHARACTER TO HEX CONVERSION TABLE char hex char hex char hex € 80 ª AA Õ D5  81 « AB Ö D6 ‚ 82 ¬

Page 127

®PowerScan D8330/M8300Reference ManualAustraliaDatalogic Scanning Pty LtdNorth Ryde, AustraliaTelephone: [61] (2) 9870 3200Fax: [61] (2) 9878 8688Fra

Page 128

POWERSCAN® D8330/M8300 14 Portable Desktop Use 1. Correctly position the BC-80X0/C-8000 onto the base by sliding it along the mounting tabs until

Page 129

INSTALLATION 15 4. Position the cables to be connected to the BC-80X0/C-8000 cradle along the dedicated channels, as shown in the figures below:

Page 130

POWERSCAN® D8330/M8300 16 2.10.2 Wall Mounting 1. Remove the yellow caps and insert the two wall mounting lock hinges provided with your cradl

Page 131

INSTALLATION 17 If using the adhesive strips: a. Carefully clean the adhesive strip seats of the base to remove any impurities that could reduce ad

Page 132

POWERSCAN® D8330/M8300 18 3 POWERSCAN® M8300 SYSTEM AND NETWORK LAYOUTS There are two basic system layouts that can be employed: Stand-alone sys

Page 133

POWERSCAN® M8300 SYSTEM AND NETWORK LAYOUTS 19 3.1.3 Multiple Stand-Alone Layouts Many stand-alone connections can operate in the same physical are

Page 134

POWERSCAN® D8330/M8300 20 3.1.4 C-BOX Layout In this layout the BC-80X0 cradle is connected by a dedicated cable using the RS-232 interface t

Page 135

POWERSCAN® M8300 SYSTEM AND NETWORK LAYOUTS 21 3.2 MULTIDROP STAR-SYSTEM™ NETWORK LAYOUTS Even though many stand-alone systems can operate in the s

Page 136

iii CONTENTS 1 INTRODUCTION ... 1 2 INSTALLATION...

Page 137 - RADIO PARAMETERS

POWERSCAN® D8330/M8300 22 3.2.2 BC-8060 Master Layout A. Host B. BC-8060 Master cradle C. BC-8060 Slave cradles D. STARGATE™ base station Ex

Page 138

POWERSCAN® M8300 SYSTEM AND NETWORK LAYOUTS 23 3.2.3 Master BC-8060 Network Troubleshooting Two diagnostic strings can be sent via RS-232 from the

Page 139

POWERSCAN® D8330/M8300 24 4 CONFIGURATION 4.1 CONFIGURATION METHODS 4.1.1 Reading Configuration Barcodes This manual can be used for complete

Page 140 - ONTROL FOR

CONFIGURATION 25 4.1.4 Sending Configuration Strings from Host An alternative configuration method is provided in Appendix A using the RS-232 interfa

Page 141

POWERSCAN® D8330/M8300 26 4.3 POWERSCAN® D8330 SETUP 1. Read the restore default parameters code below. Restore PowerScan® D8330 Default Ì$+$*oÎ

Page 142

CONFIGURATION 27 4.5 POWERSCAN® M8300/BC-80X0 STAND-ALONE SETUP Read the restore default parameters code below. Restore PowerScan® M8300 Default 1

Page 143 - DISPLAY PARAMETERS

POWERSCAN® D8330/M8300 28 Set Radio Address 5. ÌRA0RFHÎ + four digits for the PowerScan® M8300 Address (from 0000 to 1999). All readers used in

Page 144

CONFIGURATION 29 Read the BC-80X0 restore default code: 9. Restore BC-80X0 Default Ì$+RX0$-qÎ Go to par. 4.8 Interface Selection. 4.5.1 Using

Page 145

POWERSCAN® D8330/M8300 30 4.5.2 PowerScan® M8300/STAR-Modem™ in Stand-Alone Mode To configure a PowerScan® M8300 reader to communicate with STAR-

Page 146

CONFIGURATION 31 4.6 POWERSCAN® M8300/STAR-SYSTEM™ SETUP The following procedure allows configuring a PowerScan® M8300 reader to communicate with va

Page 147 - 5 REFERENCES

iv 4.6 PowerScan® M8300/STAR-System™ Setup ...31 4.7 BC-8000 STAR-System™ Network Setup ...

Page 148 - 5.1.2 ACK/NACK Protocol

POWERSCAN® D8330/M8300 32 Set Radio Address 6. ÌRF8Î + four digits from the Numeric Table in the range 0000-1999. All readers must have different

Page 149 - 5.1.3 FIFO

CONFIGURATION 33 4.7 BC-8060 STAR-SYSTEM™ NETWORK SETUP When the BC-8060 cradle model is used in an RS-485 network, it must be initially configured.

Page 150 - 5.2.1 Minimum Output Pulse

POWERSCAN® D8330/M8300 34 Read the BC-8060 restore default code: 5. Restore BC-8060 Default Ì$+RX0$-qÎ Read the desired Enable Network code.

Page 151 - 5.2.3 Overflow

CONFIGURATION 35 4.8 INTERFACE SELECTION Read the interface selection code for your application. RS-232 Standard Ì$+CP0$-$Î POS TERMINALS Ni

Page 152 - 5.3 NETWORK PARAMETERS

POWERSCAN® D8330/M8300 36 WEDGE IBM AT or PS/2 PCs Ì$+CP500$-aÎ IBM XT PC Notebook Ì$+CP503$-vÎ Ì$+CP505$-ÈÎ IBM SURE1 IBM Termi

Page 153 - 5.4 DATA FORMAT

CONFIGURATION 37 WEDGE (CONTINUED) ALT MODE The ALT-mode selection allows barcodes sent to the PC to be interpreted correctly independently from the

Page 154

POWERSCAN® D8330/M8300 38 4.9 USB READER CONFIGURATION The USB interface is available for PowerScan® D8330, BC-80x0 and C-8000 devices and is com

Page 155 - Enter Configuration

CONFIGURATION 39 USB USB-KBD Ì$+UA03$-:Î USB-KBD-ALT-MODE Ì$+UA04$-@Î USB-KBD-APPLE Ì$+UA05$-FÎ USB-COM* Ì$+UA02$-4Î USB-IBM-Table Top Ì

Page 156

POWERSCAN® D8330/M8300 40 4.10 CHANGING DEFAULT SETTINGS Once your reader is setup, you can change the default parameters to meet your applicati

Page 157

41 RS-232 PARAMETERS All PowerScan® D8330 Series readers + PowerScan® M8300/BC-80X0 configurations only ~ BAUD RATE ~ ~ PARITY ~ ~ DATA BITS ~ ~

Page 158 - D8330/M8300

v 5.9.1 Radio Protocol Timeout ... 158 5.9.2 Radio RX Timeout...

Page 159

Enter Configuration Exit and Save Configuration Ì$+;Î RS-232 Ì$-?Î 42 BAUD RATE 300 baud ÌCD1XÎ 600 baud 1200 baud ÌCD2[Î ÌCD3^Î

Page 160 - ÌFQ9C2>Î

Enter Configuration Exit and Save Configuration Ì$+;Î RS-232 Ì$-?Î 43 DATA BITS 7 bits ÌCA0OÎ  8 bits 9 bits ÌCA1RÎ ÌCA2UÎ STOP B

Page 161

Enter Configuration Exit and Save Configuration Ì$+;Î RS-232 Ì$-?Î 44 ACK/NACK PROTOCOL  disable ÌER0sÎ enable ÌER1vÎ See par. 5.1.2

Page 162 - 5.4.4 Address Delimiter

Enter Configuration Exit and Save Configuration Ì$+;Î RS-232 Ì$-?Î 45 RX TIMEOUT timeout control in reception from Host ÌCL5Î Read 2 numbers fro

Page 163 - 5.5.1 Sleep State

46 USB PARAMETERS ~ USB-COM Handshaking, Ack/Nack protocol, FIFO, Inter-character delay, Rx timeout, Serial trigger lock ~ ~ USB-KBD Keyboard na

Page 164

Enter Configuration Exit and Save Configuration Ì$+;Î USB-COM Ì$-?Î 47 HANDSHAKING  disable ÌCE0WÎ hardware (RTS/CTS) software (XON/XO

Page 165 - 5.7.2 Overflow Control

Enter Configuration Exit and Save Configuration Ì$+;Î USB-COM Ì$-?Î 48 INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î

Page 166 - 5.8.1 Match Conditions

Enter Configuration Exit and Save Configuration Ì$+;Î USB-KBD Ì$-?Î 49 KEYBOARD NATIONALITY Not Available for USB-KBD-ALT-MODE Interface This par

Page 167 - 5.9.3 Power-Off Timeout

Enter Configuration Exit and Save Configuration Ì$+;Î USB-KBD Ì$-?Î 50 The Japanese and Eastern Block Keyboard Nationality selections are valid

Page 168 - 5.9.4 Transmission Mode

Enter Configuration Exit and Save Configuration Ì$+;Î USB-KBD Ì$-?Î 51 INTER-CHARACTER DELAY delay between characters transmitted to Host ÌCK3Î

Page 169 - 5.9.7 Batch Mode

vi GENERAL VIEW POWERSCAN® D8330/M8300 READERS Figure A – PowerScan® D8330/M8300 Series Readers Figure B – PowerScan® M8300 Series Readers

Page 170 - M8300 only)

52 WEDGE PARAMETERS All PowerScan® D8330 Series readers + PowerScan® M8300/BC-80X0 configurations only ~ KEYBOARD NATIONALITY ~ ~ CAPS LOCK ~ ~

Page 171 - 5.10.1 Display Mode

Enter Configuration Exit and Save Configuration Ì$+;Î WEDGE Ì$-?Î 53 KEYBOARD NATIONALITY Belgian ÌFJ7yÎ English (UK) French ÌFJ4pÎ ÌFJ

Page 172

Enter Configuration Exit and Save Configuration Ì$+;Î WEDGE Ì$-?Î 54 The Japanese and Eastern Block Keyboard Nationality selections are valid on

Page 173 - Ì#+CODEÂÎ

Enter Configuration Exit and Save Configuration Ì$+;Î WEDGE Ì$-?Î 55 CAPS LOCK AUTO-RECOGNITION (IBM AT COMPATIBLE ONLY) disable ÌFP0pÎ  e

Page 174 - Ì$+ZZ0$-*Î

Enter Configuration Exit and Save Configuration Ì$+;Î WEDGE Ì$-?Î 56 INTER-CODE DELAY delay between codes transmitted to Host ÌFG.Î Read 2 num

Page 175 - Ì$+ZZ2$-4Î

WEDGE 57 Some ASCII characters may be missing as this depends on the type of keyboard: these are generally particular characters relative to the

Page 176 - Ì$+ZZ3$-9Î

Enter Configuration Exit and Save Configuration Ì$+;Î WEDGE Ì$-?Î 58 CONTROL CHARACTER EMULATION  Ctrl + Shift + Key ÌFO0nÎ Ctrl + Key

Page 177

59 PEN EMULATION All PowerScan® D8330 Series readers + PowerScan® M8300/BC-80X0 configurations only ~ OPERATING MODE ~ ~ MINIMUM OUTPUT PULSE ~ ~

Page 178 - Ì$+RN2$-SÎ

PEN EMULATION 60 The operating mode parameters are complete commands and do not require reading the Enter and Exit configuration codes. OPERATIN

Page 179 - 6 MESSAGE FORMATTING

Enter Configuration Exit and Save Configuration Ì$+;Î PEN EMULATION Ì$-?Î 61 MINIMUM OUTPUT PULSE 200 μs ÌDG0\Î 400 μs  600 μs

Page 180 - 6.1.1 Cursor Control

vii BC-80X0 / C-8000 CRADLES Figure C – BC-8000 The label on the cradle contains LED indicators and a scan finder button. When the button is presse

Page 181 - 6.1.3 Clearing Display

Enter Configuration Exit and Save Configuration Ì$+;Î PEN EMULATION Ì$-?Î 62 CONVERSION TO CODE 39 (D8330 SERIES ONLY)  disable conversion to

Page 182 - 6.1.5 Setting RTC

Enter Configuration Exit and Save Configuration Ì$+;Î PEN EMULATION Ì$-?Î 63 OUTPUT LEVEL  normal ÌDD0VÎ (white = logic level 0) inverte

Page 183 - MESSAGE FORMATTING

64 NETWORK PARAMETERS BC-8060 model configurations only ~ RS-485 NETWORK ~ ~ NETWORK BAUD RATE ~ ~ SLAVE ADDRESS RANGE ~ ~ NETWORK WARNING MESSA

Page 184 - 7 TECHNICAL FEATURES

Enter Configuration Exit and Save Configuration Ì$+;Î NETWORK PARAMETERS Ì$-?Î 65 RS-485 NETWORK  disable RS-485 network ÌRZ0)Î enable RS

Page 185 - IEC 68-2-32 Test ED

Enter Configuration Exit and Save Configuration Ì$+;Î NETWORK PARAMETERS Ì$-?Î 66 SLAVE ADDRESS RANGE First Address ÌJB(Î Read the code above

Page 186 - 7.3 BC-80X0 / C-8000

Enter Configuration Exit and Save Configuration Ì$+;Î NETWORK PARAMETERS Ì$-?Î 67 MASTER CRADLE HEADER  no header ÌJA00/Î one characte

Page 187 - 7.5 STATUS INDICATORS

Enter Configuration Exit and Save Configuration Ì$+;Î NETWORK PARAMETERS Ì$-?Î 68 MASTER CRADLE TERMINATOR  no terminator ÌJA102Î on

Page 188

69 DATA FORMAT NOT FOR PEN INTERFACES ~ CODE IDENTIFIER ~ ~ CUSTOM CODE IDENTIFIER ~ ~ HEADER ~ ~ TERMINATOR ~ ~ SPECIAL KEYS ~ ~ FIELD ADJUSTMENT

Page 189

DATA FORMAT 70 CODE IDENTIFIER TABLE CODE AIM STANDARD DATALOGIC STANDARD Custom 2/5 interleaved ] I y N 2/5 industrial ] X y P 2/5 norm

Page 190 - 7.6 READING DIAGRAMS

Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 71 CODE IDENTIFIER  disable ÌEB0SÎ Datalogic standard AIM stan

Page 192 - SERIAL CONFIGURATION STRINGS

Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 72 HEADER no header ÌEA00*Î one character header two char

Page 193 - (100 ms) CL00 - CL99

Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 73 TERMINATOR no terminator ÌEA10-Î one character terminator

Page 194 - (IBM AT compatible only)

Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 74 SPECIAL KEYS Available only for Wedge IBM AT-PS/2 and USB-KBD Interf

Page 195

Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 75 FIELD ADJUSTMENT  disable field adjustment ÌEF0[Î Field adjustment a

Page 196 - (100 ms) CK00-CK99

Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 76 FIELD ADJUSTMENT CHARACTER c Read the field adjustment character c

Page 197

Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 77 CHARACTER REPLACEMENT  disable character replacement ÌEO0mÎ This par

Page 198

Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 78 Example: The following strings define: 1. First Character Replacem

Page 199 - (only for D8330 series)

Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 79 ADDRESS STAMPING (M8300 SERIES ONLY)  disable reader address stampin

Page 200

Enter Configuration Exit and Save Configuration Ì$+;Î DATA FORMAT Ì$-?Î 80 TIME STAMPING (M8300 SERIES ONLY)  disable ÌIL0kÎ hour/minutes

Page 201

81 POWER SAVE ~ SLEEP STATE ~ ~ ENTER SLEEP TIMEOUT ~ 1. Read the Enter Configuration code ONCE, available at the top of each pa

Page 202

INTRODUCTION 1 1 INTRODUCTION Datalogic renews its range of industrial laser scanners introducing the PowerScan® family: PowerScan® D8330 and Powe

Page 203

Enter Configuration Exit and Save Configuration Ì$+;Î POWER SAVE Ì$-?Î 82 SLEEP STATE  disable ÌBQ0nÎ enable ÌBQ1qÎ See par. 5.5.1 f

Page 204

83 READING PARAMETERS ~ TRIGGER TYPE ~ ~ TRIGGER SIGNAL ~ ~ TRIGGER CLICK ~ ~ TRIGGER-OFF TIMEOUT ~ ~ FLASH MODE ~ ~ READS PER CYCLE ~ ~ SAFETY TI

Page 205 - B CODE IDENTIFIER TABLE

Enter Configuration Exit and Save Configuration Ì$+;Î READING PARAMETERS Ì$-?Î 84 TRIGGER TYPE  hardware trigger ÌBK1eÎ Restores TRIGGER MOD

Page 206

Enter Configuration Exit and Save Configuration Ì$+;Î READING PARAMETERS Ì$-?Î 85 TRIGGER-OFF TIMEOUT trigger-off timeout ÌBD$Î Read 2 numbers i

Page 207

Enter Configuration Exit and Save Configuration Ì$+;Î READING PARAMETERS Ì$-?Î 86 SAFETY TIME safety time ÌBE&Î Limits same code consecutiv

Page 208 - C HEX AND NUMERIC TABLE

Enter Configuration Exit and Save Configuration Ì$+;Î READING PARAMETERS Ì$-?Î 87 BEEPER TONE tone 1 ÌBH0\Î  tone 2 tone 3 ÌBH1_Î ÌBH2

Page 209 - HEX / NUMERIC TABLE

Enter Configuration Exit and Save Configuration Ì$+;Î READING PARAMETERS Ì$-?Î 88 GOOD READ SPOT DURATION disable ÌBV0xÎ short  medi

Page 210

89 DECODING PARAMETERS ~ INK SPREAD ~ ~ OVERFLOW CONTROL ~ ~ INTERDIGIT CONTROL ~ ~ DECODING SAFETY ~ ~ PUZZLE SOLVER™ ~ CAUTION Before chang

Page 211

Enter Configuration Exit and Save Configuration Ì$+;Î DECODING PARAMETERS Ì$-?Î 90 INK SPREAD disable ÌAX0{Î  enable ÌAX1~Î See par.

Page 212

Enter Configuration Exit and Save Configuration Ì$+;Î DECODING PARAMETERS Ì$-?Î 91 DECODING SAFETY  one read ÌED0WÎ (decoding safety disabled)

Related models: POWERSCAN M8300

Comments to this Manuals

No comments