Datalogic Jet™User’s Manual©2004-2007 Datalogic Mobile S.r.l.822000645 (Rev. F)11/07www.mobile.datalogic.comDatalogic Mobile S.r.l.Via S. Vitalino, 1
ESPAÑOL Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso cor
EEPROM Electrically Erasable Programmable Read-Only Memory. An on-board non-volatile memory chip. Flash Disk Non-volatile memory for storing applica
RFID (Radio frequency identification) A technology that incorporates the use of electromagnetic or electrostatic coupling in the radio frequency (RF)
INDEX A Accessories; 5 Available Models; 2 B Backup Directory File Management; 69 Bluetooth Approval; vi Bluetooth® Manager Device Setup; 59 Buttons
Laser Safety; vii Radio Compliance; x SAR Compliance; xii WEEE Compliance; xiii Save Session; 45 Scan Parameters; 36 Services and Support; v SIM Card
07Datalogic Mobile S.r.l. Via San Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheini
ETSI EN 300 328 V1.6.1, NOVEMBER 2004: ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); WIDEBAND TRANSMISSION SYSTEMS; DATA TRANSMISS
Datalogic Jet™User’s Manual©2004-2007 Datalogic Mobile S.r.l.822000645 (Rev. F)11/07www.mobile.datalogic.comDatalogic Mobile S.r.l.Via S. Vitalino, 1
The following shows the correspondence between the Datalogic Jet™ models and the Radio modules: DLBJET™ 5XX-XXX-XXX 802.11b (Wi-Fi) radio card
FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the eq
WEEE COMPLIANCE Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC L’apparecchiatura che riporta il simbolo del bidone barra
éviter les retombées négatives pour l'environnement et la santé dérivant d'une élimination incorrecte récupérer les matériaux dans le
xv GENERAL VIEW Figure A – General View A) Data capture/Laser output window B) Scan key(s) (3) C) Bluetooth® LED D)
INTRODUCTION 1 1 INTRODUCTION 1.1 DATALOGIC JET™ PDA DESCRIPTION The Datalogic Jet™, is the powerful Datalogic PDA. Thanks to the state-of the-art
DATALOGIC JET™ 2 1 1.2 AVAILABLE MODELS The Datalogic Jet™ PDA is available in different models depending on the options it is equipped with. All o
INTRODUCTION 3 1 1.4 INSERTING MINI SD CARD With Datalogic Jet™ PDA, it is possible to add a Mini SD Card for additional storage capacity. To acces
Datalogic Mobile S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy Datalogic Jet™ - User's Manual Ed.:
DATALOGIC JET™ 1 CAUTION Follow proper ESD precautions to avoid damaging the SD. Proper ESD precautions include, but are not limited to, working on
INTRODUCTION 1 1.5 ACCESSORIES Cradles 94A151096 Datalogic Jet™ Single Cradle Desk (includes slot for spare battery pack recharge; RS232 and USB co
DATALOGIC JET™ 1 NOTE Use only a Datalogic Mobile-approved power supply and cables. Use of an alternative power supply will invalidate any approval g
CONNECTIONS 2 2 CONNECTIONS 2.1 PDA CONNECTION TO THE HOST COMPUTER 2.1.1 RS232/USB Direct Connection You can use a cable to connect the Datalo
DATALOGIC JET™ 2 2.1.2 WLAN Connection Datalogic Jet™ Wi-Fi 802.11b and Wi-Fi 802.11b/g1 models can communicate with the host using the on-board radi
CONNECTIONS 2 NOTE Wi-Fi module is on by default. In order to avoid wasting energy, you can switch it off using the Wireless Communications applet (
DATALOGIC JET™ 2 2.1.3 WPAN Connection Datalogic Jet™ PDAs can communicate with a Bluetooth® device, such as a printer, within a range of 10 m, using
CONNECTIONS 2 NOTE Area coverage and Bluetooth radio performance may vary, due to environmental conditions or interference caused by other devices (m
DATALOGIC JET™ 2 2.1.4 WWAN Connection Datalogic Jet™ GSM/GPRS models enhance your connectivity solutions giving you an opening to an international w
CONNECTIONS 2 13
CONTENTS REFERENCES ... v Conventions ...
DATALOGIC JET™ 2 Installing the SIM Card To correctly insert the SIM Card, proceed as follows: 1- Turn off the Datalogic Jet™ PDA. 2- Press the la
CONNECTIONS 2 4- Open the Sim Card slot by pulling up the locking plate. 5- Pull up the cardholder and insert the Sim Card with its contacts dow
DATALOGIC JET™ 2 CAUTION Follow proper ESD precautions to avoid damaging the SIM card. Proper ESD precautions include, but are not limited to, worki
CONNECTIONS 2 2.2 CONNECTION CABLES The following cables are listed with their order number. RS232 Direct Connection: 94A051008 WIN-NET SERIAL CAB
DATALOGIC JET™ 3 3 USE AND FUNCTIONING The use of the Datalogic Jet™ PDA depends on the application software loaded. However there are several para
USE AND FUNCTIONING 3 When it is no longer used for more than a programmable timeout, which is defined in the POWER applet of the Control Panel, the P
DATALOGIC JET™ 3 CAUTION Use only original Datalogic styluses supplied with the product itself. In harsh applications, use of screen protectors sh
USE AND FUNCTIONING 3 3.3 DATA CAPTURE To capture data, first of all select the barcode icon on the bottom-right side of the display and tap the &apo
DATALOGIC JET™ 3 3.3.2 Imager Data Capture To read a 1D or 2D code, simply point the Datalogic Jet™ Imager model onto the code from a distance withi
USE AND FUNCTIONING 3 Linear barcode 2D Matrix symbol ÌBX3ÉÎ Relative Size and Location of Aiming System Pattern The field of view changes its siz
3.4.3 Key Selection... 25 3.5 Status Indicators ...
DATALOGIC JET™ 3 3.4 DESCRIPTION OF THE KEYS The Datalogic Jet™ PDA provides a function-oriented keyboard having a total of 27 keys. The keyboard ca
USE AND FUNCTIONING 3 3.4.2 Key Selection The following figure shows the Datalogic Jet™ PDA keyboard: 25
DATALOGIC JET™ 3 Some of these keys carry extra symbols and are logically divided in up to 3 sections according to the following figure: A B C E
USE AND FUNCTIONING 3 Switches on/off the keyboard backlight. Both display and keyboard backlight automatically turn off after a timeout, depending o
DATALOGIC JET™ 3 3.4.3 Resetting the Jet Windows CE There are several reset methods for the Jet. A warm boot terminates an unresponsive applicatio
USE AND FUNCTIONING 3 To perform a clean boot, follow these steps: 1. Perform a Cold Boot (see Cold Boot). 2. Quickly release all the keys when the
DATALOGIC JET™ 3 Cold Boot A cold boot is a complete reset of the Jet in which all applications are forcibly closed and the RAM is completely cleared.
USE AND FUNCTIONING 3 3.5 STATUS INDICATORS 3.5.1 LED Status The Datalogic Jet™ provides three different LEDs signaling the PDA status. LED STATUS
DATALOGIC JET™ 3 3.5.2 Taskbar As well as tasks opened in Windows, the Taskbar provides several status icons that report information about the time,
USE AND FUNCTIONING 3 Windows CE Taskbar Windows Mobile Taskbars 33
REFERENCES CONVENTIONS This manual uses the following conventions: “User” refers to anyone using a Datalogic Jet™ PDA. “PDA” and " Datalogic
DATALOGIC JET™ 3 3.6 DATA CAPTURE CONFIGURATION From the Windows CE Taskbar, tap the "Data Capture" icon to open a drop–down menu. Data Ca
USE AND FUNCTIONING 3 The Scan Parameters are common to all scanner modules and allow control of the scanning device (i.e. beeper control, LED control
DATALOGIC JET™ 3 Selecting Data Capture Setup Parameters Alternatively using the stylus, you can tap once directly on the value on the right colu
USE AND FUNCTIONING 3 ContinuousMode: when enabled, the scanner can only be turned off by releasing the SCAN key, or if Soft Trigger is enabled, by th
DATALOGIC JET™ 3 Default Settings The following tables contain the default values for the major barcode setup parameters, according to the type of sc
USE AND FUNCTIONING 3 BARCODE SYMBOLOGY SPECIFIC READER PARAMETERS HP Laser Imager RFID+Laser MSI Enabled Disabled Plessey Disabled Code 93 Di
DATALOGIC JET™ 3 3.6.2 Capture The Data Capture applet (Capture) enables code reading. Data Capture Window Data Capture can also be enabled throug
USE AND FUNCTIONING 3 3.7 CONTROL PANEL From the Windows CE Desktop, double tap on the "Control Panel" icon to open the Windows CE control
DATALOGIC JET™ 3 3.7.1 Buttons The BUTTONS Applet allows assigning desired applications to be launched by one of the function keys (F1, F2, F3, F4).
USE AND FUNCTIONING 3 Select the “Enable Multipress” check box to enable multipress text input mode. To enables F5, F6, F7, F8, F9, F10 function keys,
SAFETY REGULATIONS NOTE Read this manual carefully before performing any type of connection to the Datalogic Jet™ PDA. The user is responsible for
DATALOGIC JET™ 3 3.7.2 Registry The REGISTRY ADMIN applet provides management of Windows CE/ Windows Mobile registry. From the Windows CE control p
USE AND FUNCTIONING 3 3.7.3 Files Admin The FILES ADMIN applet enables control of the permanence of files in the Windows CE System Folder. Because W
DATALOGIC JET™ 3 Two activating procedures are available for Safe Setup: - Select an installation file (for example, a .CAB cabinet file) from the S
USE AND FUNCTIONING 3 Safe Setup Second Mask 47
DATALOGIC JET™ 3 3.7.4 Wireless Communications The WIRELESS COMMUNICATIONS applet provides management of the Wi-Fi Card and of the Bluetooth® and GSM
USE AND FUNCTIONING 3 If the PDA supports Windows Mobile, the Wireless Manager application manages access to wireless connections. The 'Wireless
DATALOGIC JET™ 3 3.7.5 Ethernet Settings Windows CE Ethernet cradle Datalogic Jet™ can be connected to an Ethernet network by inserting it into the
USE AND FUNCTIONING 3 The LAN icon will appear on the Taskbar indicating the LAN connection status. By double tapping on the LAN icon in the Taskbar,
DATALOGIC JET™ 3 then ensure that the USB/Ethernet Adapter card connects to Work -> go to Start -> Settings -> Connections -> Connectio
USE AND FUNCTIONING 3 3.7.6 Volume Settings From the Windows CE control panel main window, select the VOLUME SETTINGS applet by double tapping the Vo
LASER SAFETY The laser light is visible to the human eye and is emitted from the window indicated in the figure. This information applies to both La
DATALOGIC JET™ 3 - GSM: it is automatically activated each time a phone-call is started. It is not available when using the cradle loudspeaker (in th
USE AND FUNCTIONING 3 Cradle Tab It allows selecting the cradle type and managing the vehicle cradle headset functioning: Two radio buttons allow
DATALOGIC JET™ 3 WARNING Do not use the vehicle cradle headset if the headset button is disabled, since it may cause hearing damage. 56
USE AND FUNCTIONING 3 3.8 WINDOWS CONNECTIONS To connect the PDA to another device (i.e. Host PC) from Windows, several programs are available in the
DATALOGIC JET™ 3 NOTE In Windows Mobile before using the ActiveSync follow the directions described in 2.1.1 NOTE Visit the following Microsoft Web
USE AND FUNCTIONING 3 3.8.2 Bluetooth® Manager Device Setup Windows CE Bluetooth® Manager Device Setup In order to enable a Bluetooth® device for
DATALOGIC JET™ 3 3. Tap on the “Me” button to enter the related window; then, tap on the “ON” button to activate the Bluetooth® module. The module ac
USE AND FUNCTIONING 3 Once the Discovery procedure has been completed, select the desired Bluetooth® device from the list. It is also possible to digi
DATALOGIC JET™ 3 Windows Mobile Bluetooth® Manager Device Setup Before turning on Bluetooth®, ensure that the two devices are within close range and
USE AND FUNCTIONING 3 3. Tap the name of the other device, and tap Next: 4. In Passkey, if you want to use a passkey (recommended for enhanced
ENGLISH The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your PDA
DATALOGIC JET™ 3 5. Enter the same passkey on the other device. 6. To give the partnership a more meaningful name, change the name of the device
USE AND FUNCTIONING 3 Other devices with Bluetooth® capabilities can detect your device and attempt to beam information to it, establish a partnersh
DATALOGIC JET™ 3 If you no longer want your device to be discoverable, clear the “Make this device visible to other devices” check box. Your device
USE AND FUNCTIONING 3 4. When prompted to receive an incoming beam, tap “Yes” to receive the beamed information. 67
DATALOGIC JET™ 3 3.8.3 FTP Server Setup The Datalogic Jet™ Windows CE Operating System includes a sample File Transfer Protocol (FTP) server. FTP is
USE AND FUNCTIONING 3 3.9 BACKUP DIRECTORY FILE MANAGEMENT All of the Windows CE system files reside in RAM (volatile memory) except for the Backup
DATALOGIC JET™ 4 4 MAINTENANCE NOTE Rechargeable battery packs are not initially charged. Therefore the first operation to perform is to charge the
MAINTENANCE 4 NOTE Even if the storage temperature range is wider, In order to achieve the longest battery life, store the terminal and the spare ba
DATALOGIC JET™ 4 4.2 REPLACING THE BATTERY PACK To correctly replace the battery pack, proceed as follows. 1. Turn off the Datalogic Jet™ PDA. 2.
MAINTENANCE 4 4. Replace the battery pack by pressing the latch release button and pulling the battery latch down, and then by inserting it towards t
DEUTSCH Die folgenden Informationen stimmen mit den Sicherheitshinweisen überein, die von internationalen Behörden auferlegt wurden, und sie beziehen
DATALOGIC JET™ 4 WARNING Use only a Datalogic Mobile approved power supply. Use of an alternative power supply will void the product warranty and ma
MAINTENANCE 4 NOTE In order to guarantee an adequate operating autonomy, when replacing the battery pack the PDA checks the battery energy level. If
DATALOGIC JET™ 5 5 TECHNICAL FEATURES 5.1 TECHNICAL DATA Datalogic Jet™ Common Features Electrical Features Power DC supply 12 to 14 V ± 5% B
TECHNICAL FEATURES 5 Mechanical Features Dimensions (LxWxH) 17.6 x 9 x 2.8 cm / 6.9 x 3.5 x 1.1 in Weight (depending on model) 424– 465 g / 14.9–
DATALOGIC JET™ 5 Datalogic Jet™ Imager Optical Features Optical Features Max. resolution 1D Codes 0.10 mm / 4 mils 2D Codes 0.17 mm / 6.6 mils Sk
TECHNICAL FEATURES 5 5.2 READING DIAGRAMS DLBJET™ HP Laser (XXX-1XX-XXX models) Reading Zones (10° skew angle)100 200 400200 100 0 100 200 300 5006
DATALOGIC JET™ 6 6 TEST CODES High Density Codes 0.25 mm (10 mils) Code 39 !17162H! 17162 2/5 Interleaved Ë"8NduÌ 0123456784
TEST CODES 6 Medium Density Codes 0.38 mm (15 mils) Code 39 !17162H! 17162 Interleaved 2/5 Ë"8NduÌ 0123456784 Code 12
DATALOGIC JET™ 6 Low Density Codes 0.50 mm (20 mils) Code 39 !17162H! 17162 Interleaved 2/5 Ë"8NduÌ 0123456784 Code 128 Ìte
GLOSSARY Access Point A device that provides transparent access between Ethernet wired networks and IEEE 802.11 interoperable radio-equipped mobile
Comments to this Manuals