MagellanTM 1000iOn-Counter Presentation Omnidirectional Bar Code ReaderProduct Reference Guide
Getting Started1-4 Magellan® 1000iLED and Beeper IndicatorsThe scanner’s beeper sounds and its green LED illuminates to indicate various functions or
Symbologies5-24 Magellan® 1000iGS1 DataBar LimitedThe following options apply to the GS1 DataBar Limited symbology.Disable/Enable GS1 DataBar LimitedW
GS1 DataBar LimitedProduct Reference Guide 5-25GS1 DataBar Limited — continuedMinimum ReadsThis feature specifies the minim
Symbologies5-26 Magellan® 1000iCode 39The following options apply to the Code 39 symbology.Disable/Enable Code 39When this feature is disabled, the sc
Code 39Product Reference Guide 5-27Check Character TransmitEnable this option to transmit the check character with scanned
Symbologies5-28 Magellan® 1000iCode 39 Full ASCIIEnables/disables the translation of Code 39 characters to Code 39 full-ASCII characters.START / ENDPR
Code 39Product Reference Guide 5-29Code 39 — continuedLength ControlFixed Length Decoding— When fixed length decoding is en
Symbologies5-30 Magellan® 1000iCode 39 Length 1, Length 2 Programming Instructions1. Scan the START/END barcode.2. Scan either the Set Length 1 or Set
Code 39Product Reference Guide 5-31Code 39 — continuedCode 39 StitchingEnables/disables stitching for Code 39 labels. When
Symbologies5-32 Magellan® 1000iPharmacode 39The following options apply to the Pharmacode 39 symbology.Disable/Enable Pharmacode 39When this feature i
Pharmacode 39Product Reference Guide 5-33Check Character TransmitEnable this option to transmit the check character with sc
Error CodesProduct Reference Guide 1-5Error CodesUpon startup, if the scanner flashes its indicator LED or sounds an unexpe
Symbologies5-34 Magellan® 1000iCode 128The following options apply to the Code 128 symbology.Disable/Enable Code 128When this feature is disabled, the
Code 128Product Reference Guide 5-35Code 128 — continuedTransmit Function CharactersEnables/disables transmission of Code12
Symbologies5-36 Magellan® 1000iCode 128 — continuedLength ControlFixed Length Decoding— When fixed length decoding is enabled, the scanner will decode
Code 128Product Reference Guide 5-37Code 128 — continuedCode 128 Length 1, Length 2 Programming Instructions1. Scan the STA
Symbologies5-38 Magellan® 1000iCode 128 — continuedCode 128 StitchingEnables/disables stitching for Code 128 labels. When parts of a Code 128 barcode
Interleaved 2 of 5Product Reference Guide 5-39Interleaved 2 of 5The following options apply to the Interleaved 2 of 5 (I 2
Symbologies5-40 Magellan® 1000iInterleaved 2 of 5 — continuedCheck Digit TransmitEnable this option to transmit the check digit with scanned barcode d
Interleaved 2 of 5Product Reference Guide 5-41Interleaved 2 of 5 — continuedLength ControlFixed Length Decoding— When fixed
Symbologies5-42 Magellan® 1000iInterleaved 2 of 5 — continuedInterleaved 2 of 5 Length 1, Length 2 Programming Instructions1. Scan the START barcode.2
Interleaved 2 of 5Product Reference Guide 5-43Interleaved 2 of 5 — continuedInterleaved 2 of 5 StitchingEnables/disables st
Getting Started1-6 Magellan® 1000iNOTES
Symbologies5-44 Magellan® 1000iInterleaved 2 of 5 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive times an Interleave
CodabarProduct Reference Guide 5-45CodabarThe following options apply to the Codabar symbology.Disable/Enable CodabarWhen t
Symbologies5-46 Magellan® 1000iCheck Character TransmitEnable this option to transmit the check character with scanned barcode data.START / ENDPROGRAM
CodabarProduct Reference Guide 5-47Codabar — continuedLength ControlFixed Length Decoding— When fixed length decoding is en
Symbologies5-48 Magellan® 1000iCodabar — continuedCodabar Length 1, Length 2 Programming Instructions1. Scan the START barcode.2. Scan either the Set
CodabarProduct Reference Guide 5-49Codabar — continuedStart/Stop Character TypeCodabar has four pairs of Start/Stop pattern
Symbologies5-50 Magellan® 1000iStart/Stop Character MatchThis feature enables/disables the requirement that start and stop characters match.Codabar St
CodabarProduct Reference Guide 5-51Codabar — continuedMinimum ReadsThis feature specifies the minimum number of consecutive
Symbologies5-52 Magellan® 1000iCode 93The following options apply to the Code 93 symbology.Disable/Enable Code 93When this feature is disabled, the sc
Code 93Product Reference Guide 5-53Code 93 — continuedLength ControlFixed Length Decoding— When fixed length decoding is en
Product Reference Guide2-1Chapter 2General FeaturesDouble Read TimeoutThe Double Read Timeout feature sets a time limit that determines how much time
Symbologies5-54 Magellan® 1000iCode 93 — continuedCode 93 Length 1, Length 2 Programming Instructions1. Scan the START barcode.2. Scan either the Set
Code 93Product Reference Guide 5-55Code 93 — continuedCode 93 StitchingEnables/disables stitching for Code 93 barcodes. Whe
Symbologies5-56 Magellan® 1000iMSI/PlesseyThe following options apply to the MSI/Plessey symbology.Disable/Enable MSI/PlesseyWhen this feature is disa
MSI/PlesseyProduct Reference Guide 5-57MSI/Plessey — continuedCheck Digit TransmitWhen this option is enabled, the scanner
Symbologies5-58 Magellan® 1000iMSI/Plessey — continuedLength ControlFixed Length Decoding— When fixed length decoding is enabled, the scanner will dec
MSI/PlesseyProduct Reference Guide 5-59MSI/Plessey — continuedMSI/Plessey Length 1, Length 2 Programming Instructions1. Sca
Symbologies5-60 Magellan® 1000iMSI/Plessey — continuedMSI/Plessey StitchingEnables/disables stitching for MSI/Plessey barcodes. When parts of an MSI/P
MSI/PlesseyProduct Reference Guide 5-61MSI/Plessey — continuedMinimum ReadsThis feature specifies the minimum number of con
Symbologies5-62 Magellan® 1000iStandard 2 of 5The following options apply to the Standard 2 of 5 symbology.Disable/Enable Standard 2 of 5When this fea
Standard 2 of 5Product Reference Guide 5-63Standard 2 of 5 — continuedCheck Digit TransmitWhen this option is enabled, the
General Features2-2Magellan® 1000iDouble Read Timeout — cont.START / ENDPROGRAMMING BARCODES0.7 Second0.8 Second0.9 Second1 Second
Symbologies5-64 Magellan® 1000iStandard 2 of 5 — continuedLength ControlFixed Length Decoding— When fixed length decoding is enabled, the scanner will
Standard 2 of 5Product Reference Guide 5-65Standard 2 of 5 — continuedStandard 2 of 5 Length 1, Length 2 Programming Instru
Symbologies5-66 Magellan® 1000iStandard 2 of 5 — continuedStandard 2 of 5 StitchingEnables/disables stitching for Standard 2 of 5 barcodes. When parts
Standard 2 of 5Product Reference Guide 5-67Standard 2 of 5 — continuedMinimum ReadsThis feature specifies the minimum numbe
Symbologies5-68 Magellan® 1000i
Product Reference Guide6-12D Symbologies & Advanced DecodingFeaturesNOTEThe features in this section are available ONLY for models with 2D feature
2D Symbologies & Advanced Decoding Features6-2 Magellan® 1000i2D SymbologiesThe scanner supports the following 2D symbologies (barcode types): PDF
2D SymbologiesProduct Reference Guide 6-3PDF 417 — continuedLength ControlFixed Length Decoding— When fixed length decoding
2D Symbologies & Advanced Decoding Features6-4 Magellan® 1000iPDF 417 — continuedPDF 417 Length 1, Length 2 Programming Instructions1. Scan the ST
2D SymbologiesProduct Reference Guide 6-5PDF 417 — continuedMinimum ReadsThis feature specifies the minimum number of conse
Label Gone TimeoutProduct Reference Guide 2-3Label Gone TimeoutThis feature sets the time after the last label segment is s
2D Symbologies & Advanced Decoding Features6-6 Magellan® 1000iDatamatrixDisable/Enable DatamatrixWhen disabled, the scanner will not read Datamatr
2D SymbologiesProduct Reference Guide 6-7Datamatrix — continuedLength ControlFixed Length Decoding— When fixed length decod
2D Symbologies & Advanced Decoding Features6-8 Magellan® 1000iDatamatrix — continuedDatamatrix Length 1, Length 2 Programming Instructions1. Scan
2D SymbologiesProduct Reference Guide 6-9Datamatrix — continuedMinimum ReadsThis feature specifies the minimum number of co
2D Symbologies & Advanced Decoding Features6-10 Magellan® 1000iImage CaptureHow to Capture an ImageTo initiate an Image Capture, scan the IMAGE CA
Product Reference GuideA-1Chapter AProduct SpecificationsOptical and Read Performance ParametersScanner DimensionsParameter SpecificationScan Volume 7
A-2 Magellan® 1000iPhysical PropertiesElectrical ParametersEnvironmental ParametersOther ParametersParameter SpecificationDimensions (Scanner only): 3
Product Reference GuideB-1Chapter BCable PinoutsStandard Cable Pinouts (Primary Interface Cables)RS-232IBM Port 5B/9B/1712CTS34RTS5RXD6TXD78 VCC IN9GN
Cable PinoutsB-2 Magellan® 1000iUSB-OEMUSB, USB Keyboard & USB COMWand EmulationKeyboard Wedge1234D -56D +78VIN9GND101234D -56D +78 VBUS_VIN9GND10
Product Reference GuideC-1Chapter CAlpha-Numeric PadABCDEF
General Features2-4Magellan® 1000iSleep ModeThis feature specifies the amount of time with no barcode reads before the scanner enters sleep mode.START
C-2 Magellan® 1000iAlpha-Numeric Pad1230987654
Product Reference GuideD-1Appendix DDefault SettingsDefaults by SymbologyThe following is a partial list of key settings for each symbology type.Code
D-2 Magellan® 1000iInterface Default ExceptionsThe factory default settings indicated in the programming sections (in bold text) reflect factory confi
Interface Default ExceptionsProduct Reference Guide D-3Interface Default Exceptions — continuedRS-232 Wincor/NixdorfParamet
D-4 Magellan® 1000iInterface Default Exceptions — continuedWand EmulationKeyboardsKeyboard interfaces include USB Keyboard and Keyboard Wedge A-Y.Para
Product Reference GuideE-1Appendix EKeyboard Function Key MappingsKeyboard Model Cross ReferenceTa bl e E - 1 summarizes the keyboard models, their d
E-2 Magellan® 1000iTable E-2. Scanset 1 Function Key MapTable E-3. Scanset 2 Function Key MapASCII (hex)ASCII code Key Scancode00 NUL ALT right Make
Keyboard Model Cross ReferenceProduct Reference Guide E-3Table E-4. Scanset 3, 102-Key Function Key Map1B ESC ESC 76h1C FS
E-4 Magellan® 1000iTable E-5. Scanset 3 122-Key Function Key MapASCII (hex) ASCII code Key Scancode00 NUL ALT Right Make 39h01 SOH ALT Right Break F0
Keyboard Model Cross ReferenceProduct Reference Guide E-5Table E-6. Japanese DOS Function Key MapASCII value ASCII code Key
Sleep ModeProduct Reference Guide 2-5Sleep Mode — cont.START / ENDPROGRAMMING BARCODES6 Minutes7 Minutes8 Minutes9 Minutes1
E-6 Magellan® 1000iTable E-7. NEC 9801-Key Function Key MapASCII value ASCII code Key Scancode00h NUL unused n/a01h SOH CR 1Ch02h STX CAPS LOCK ON (m
Product Reference GuideF-1Chapter FHost CommandsAccepting RS-232 CommandsThe scanner responds to the following RS-232 commands:If one of the above com
F-2 Magellan® 1000iNOTES
Product Reference GuideG-1Chapter GSample Symbols0 12345678901234567890Code 1289 780330 290951BC321123456-9$123456UPC-ACode 128Code 39Code 93Interl
G-2 Magellan® 1000iSample Symbols(01)00123456789012GS1 DataBar Omni-0100123456789050GS1 DataBar Expanded
ASCII ChartASCII Char.Hex No.ASCII Char.Hex No.ASCII Char.Hex No.ASCII Char.HexNo.NULSOHSTXETXEOTENQACKBELBSHTLFVTFFCRSOSIDLEDC1DC2DC3DC4NAKSYNETBCANE
AustraliaDatalogic Scanning Pty LtdTelephone: [61] (2) 9870 [email protected] and BeneluxDatalogic Scanning SarlTelephone: [3
General Features2-6Magellan® 1000iLED and Beeper IndicatorsPower On AlertDisables or enables the indication (a single beep) that the scanner has finis
LED and Beeper IndicatorsProduct Reference Guide 2-7Good Read: When to IndicateThis feature specifies when the scanner will
Datalogic Scanning, Inc.959 Terry StreetEugene, Oregon 97402Telephone: (541) 683-5700Fax: (541) 345-7140An Unpublished Work - All rights reserved. No
General Features2-8Magellan® 1000iGood Read Beep ControlThis feature enables/disables the scanner’s ability to beep upon a successful decode of a barc
LED and Beeper IndicatorsProduct Reference Guide 2-9Good Read Beep LengthSpecifies the duration of a good read beep.START /
General Features2-10Magellan® 1000iGood Read Beep VolumeSelects the beeper volume (loudness) upon a good read beep. There are three selectable volume
Scanning FeaturesProduct Reference Guide 2-11Scanning FeaturesTargeted Scanning ModeUpon pressing the button, the scanner w
General Features2-12Magellan® 1000iTarget Mode Linger Time Specifies the time duration the scanner remains in the targeted mode of operation after rea
Scanning FeaturesProduct Reference Guide 2-13Wake Up IntensityThis feature indicates the percentage of ambient light change
General Features2-14Magellan® 1000iWake Up Intensity — cont.START / ENDPROGRAMMING BARCODES13%14%15%
Product Reference Guide3-1Chapter 3Interface Related FeaturesAt the time of this writing, the Scanner supports the interfaces listed in Tab le 3 - 1 .
Interface Related Features3-2 Magellan® 1000iTable 3-2. Keyboard Wedge Interface ReferenceI/F Type PCs SupportedA PC/XT w/Alternate Key EncodingBAT, P
Interface SelectionProduct Reference Guide 3-3Interface SelectionSTART / ENDPROGRAMMING BARCODESRS-232 StandardRS-232 Winco
Product Reference Guidei-iTable of ContentsAbout This Manual ...
Interface Related Features3-4 Magellan® 1000iInterface Selection — cont.START / ENDPROGRAMMING BARCODESKeyboard Wedge AKeyboard Wedge BKeyboard Wedge
Interface SelectionProduct Reference Guide 3-5Interface Selection — cont.START / ENDPROGRAMMING BARCODESKeyboard Wedge KKey
Interface Related Features3-6 Magellan® 1000iInterface Selection — cont.START / ENDPROGRAMMING BARCODESKeyboard Wedge TKeyboard Wedge UKeyboard Wedge
Interface FeaturesProduct Reference Guide 3-7Interface FeaturesObey/Ignore Host CommandsWhen set to ignore host commands, t
Interface Related Features3-8 Magellan® 1000iInterface Features — cont.Host Transmission BuffersSpecifies the number of host transmission(s) that may
Interface FeaturesProduct Reference Guide 3-9RS-232 Interface FeaturesSTART / ENDPROGRAMMING BARCODES1200 Baud2400 Baud4800
Interface Related Features3-10 Magellan® 1000iRS-232 Interface Features — cont.START / ENDPROGRAMMING BARCODES7 Data Bits8 Data BitsDEFAULT1 Stop BitD
Interface FeaturesProduct Reference Guide 3-11RS-232 Interface Features — cont.Hardware Flow ControlDisable Hardware Contro
Interface Related Features3-12 Magellan® 1000iRS-232 Interface Features — cont.Intercharacter DelayThis delay is inserted after each data character tr
Interface FeaturesProduct Reference Guide 3-13Intercharacter Delay — cont.Software Flow ControlDisables/Enables software co
i-ii Magellan® 1000iWand Idle State ... 3-27Signal Speed ...
Interface Related Features3-14 Magellan® 1000iRS-232 Interface Features — cont.Host EchoWhen enabled, this feature passes all data through the scanner
Interface FeaturesProduct Reference Guide 3-15RS-232 Interface Features — cont.Host Echo Quiet IntervalThis setting specifi
Interface Related Features3-16 Magellan® 1000iHost Echo Quiet Interval — cont.Signal Voltage: Normal/TTLSpecifies whether the RS-232 interface provide
Interface FeaturesProduct Reference Guide 3-17RS-232 InvertEnables/disables inversion of RS-232 TXD and RXD signals.Beep on
Interface Related Features3-18 Magellan® 1000iBeep on Not on FileSelect for the host to beep (or not) when a not-on-file (host command) condition is d
Interface FeaturesProduct Reference Guide 3-19ACK NAK OptionsThis enables/disables the ability of the scanner to support th
Interface Related Features3-20 Magellan® 1000iRS-232 Interface Features — cont. — cont.ACK CharacterNAK CharacterSTART / ENDPROGRAMMING BARCODESSets t
Interface FeaturesProduct Reference Guide 3-21RS-232 Interface Features — cont.Retry on ACK NAK TimeoutEnables/disables ret
Interface Related Features3-22 Magellan® 1000iRS-232 Interface Features — cont.ACK NAK Retry CountSTART / ENDPROGRAMMING BARCODESThis feature sets the
Interface FeaturesProduct Reference Guide 3-23RS-232 Interface Features — cont.ACK NAK Error HandlingThis item specifies th
Product Reference Guide i-iiiStart/Stop Characters ...
Interface Related Features3-24 Magellan® 1000iRS-232 Interface Features — cont.Transmission Failure IndicationEnables/disables bad-label indication up
Interface FeaturesProduct Reference Guide 3-25IBMIBM Transmit Labels in Code 39 FormatThis feature enables/disables scanner
Interface Related Features3-26 Magellan® 1000iWand EmulationSupported SymbologiesThe Wand Emulation interface will transmit barcode data as a wand dev
Interface FeaturesProduct Reference Guide 3-27Wand Emulation — cont.Bar/Space Polarity Low/High — Black will be transmitted
Interface Related Features3-28 Magellan® 1000iWand Emulation — cont.Signal SpeedThe speed of the transmission can be set. This selects the width of t
Interface FeaturesProduct Reference Guide 3-29Wand Emulation — cont.Transmit Leading NoiseThe transmission of noise pulses
Interface Related Features3-30 Magellan® 1000iKeyboard WedgeandUSB KeyboardAs a keyboard interface, the scanner supports most popular PCs and IBM term
Interface FeaturesProduct Reference Guide 3-31Keyboard Wedge — cont.START / ENDPROGRAMMING BARCODESItalyNorwayPortugalSpain
Interface Related Features3-32 Magellan® 1000iKeyboard Wedge — cont.Caps Lock StateSpecifies the format in which the scanner sends character data.STAR
Interface FeaturesProduct Reference Guide 3-33Keyboard Wedge — cont.Power-On SimulationAll PCs check the keyboard status du
i-iv Magellan® 1000iMinimum Reads ... 5-672D
Interface Related Features3-34 Magellan® 1000iControl CharactersSpecifies how the scanner transmits ASCII control characters to the host. Choices are:
Interface FeaturesProduct Reference Guide 3-35Keyboard Wedge — cont.Wedge Quiet IntervalQuiet Interval is the amount of tim
Interface Related Features3-36 Magellan® 1000iKeyboard Wedge — cont.Intercharacter DelayUSB COM Interface Set-upThis interface uses the Microsoft Wind
Product Reference Guide4-1Chapter 4Data EditingData Editing OverviewWhen a barcode is scanned, additional information can be sent to the host computer
Data Editing4-2 Magellan® 1000iGlobal Prefix/SuffixUp to 20 ASCII characters may be added as a prefix (in a position before the barcode data) and/or a
Global Prefix/SuffixProduct Reference Guide 4-3Global Prefix/Suffix — cont.START / ENDPROGRAMMING BARCODESSets up to 20 cha
Data Editing4-4 Magellan® 1000iAIM IDAIM (Automatic Identification Manufacturers) label identifiers are assigned from a globally standardized list — a
Label IDProduct Reference Guide 4-5Label IDA Label ID is a customizable code of up to two ASCII characters (00-FF), used to
Data Editing4-6 Magellan® 1000iLabel ID — cont.START / ENDPROGRAMMING BARCODESLabel ID Transmission: DisableLabel ID Position: Before Barcode DataDEFA
Label IDProduct Reference Guide 4-7Label ID — cont.START / ENDPROGRAMMING BARCODESDEFAULT SETTING FOR THIS FEATURE: E (45 h
Product Reference Guide1-1Chapter 1Getting StartedThe Magellan® 1000i Omni-Directional Imaging Scanner offers hands-free scanning for small, easily ha
Data Editing4-8 Magellan® 1000iLabel ID — cont.START / ENDPROGRAMMING BARCODESDEFAULT SETTING FOR THIS FEATURE: F (46 hex)Set EAN-13 w/P2 Addon Label
Label IDProduct Reference Guide 4-9Label ID — cont.START / ENDPROGRAMMING BARCODESDEFAULT SETTING FOR THIS FEATURE: G8 (473
Data Editing4-10 Magellan® 1000i
Label IDProduct Reference Guide 4-11Label ID — cont.START / ENDPROGRAMMING BARCODESDEFAULT SETTING FOR THIS FEATURE: % (25
Data Editing4-12 Magellan® 1000iCase ConversionThis feature can convert scanned barcode data to either all lower case (a through z) or all upper case
Character ConversionProduct Reference Guide 4-13Character ConversionCharacter conversion is an eight byte configuration ite
Data Editing4-14 Magellan® 1000i
Product Reference Guide5-1Chapter 5SymbologiesThe scanner supports the following symbologies (barcode types). Options for each symbology are included
Symbologies5-2 Magellan® 1000iUPC-A — continuedCheck Digit TransmissionEnable this option to transmit the check digit along with UPC-A barcode data.Ex
UPC-AProduct Reference Guide 5-3UPC-A — continuedNumber System TransmissionThis feature enables/disables transmission of UP
Getting Started1-2 Magellan® 1000iConnecting the ScannerThe scanner kit you ordered to match your interface should provide a compatible cable for your
Symbologies5-4 Magellan® 1000iUPC-A — continuedUPC-A In-store Minimum ReadsThis feature specifies the minimum number of consecutive times an in-store
UPC-EProduct Reference Guide 5-5UPC-EThe following options apply to the UPC-E symbology.Disable/Enable UPC-EWhen disabled,
Symbologies5-6 Magellan® 1000iUPC-E — continuedNumber System DigitThe Number System Digit (NSD) which is always a zero (0) in the leading position can
UPC-EProduct Reference Guide 5-7UPC-E — continuedExpand UPC-E to EAN13Enables/disables expansion of UPC-E labels to EAN-13.
Symbologies5-8 Magellan® 1000iGTINThe following options apply to the GTIN label data format.Expand UPC/EAN to GTINWhen this feature is enabled, the sc
EAN-13Product Reference Guide 5-9EAN-13The following options apply to the EAN-13 symbology.Disable/Enable EAN-13When disabl
Symbologies5-10 Magellan® 1000iEAN-13 — continuedEAN-13 Flag 1 CharacterEnables/disables transmission of an EAN/JAN13 Flag1 character.ISBNWhen enabled
EAN-13Product Reference Guide 5-11EAN-13 — continuedMinimum ReadsThis feature specifies the minimum number of consecutive t
Symbologies5-12 Magellan® 1000iEAN-8The following options apply to the EAN-8 symbology.Disable/Enable EAN-8When disabled, the scanner will not read EA
EAN-8Product Reference Guide 5-13EAN-8 — continuedExpand EAN-8 to EAN-13— Expands EAN-8 data to the EAN-13 data format. Sel
ProgrammingProduct Reference Guide 1-3Wand Emulation Connection — Connect the scanner to the appropriated port on the ter-m
Symbologies5-14 Magellan® 1000iEnable EAN Two-LabelEnables/disables the ability of the scanner to decode EAN two-label pairs.START / ENDPROGRAMMING BA
Add-onsProduct Reference Guide 5-15Add-onsAdd-ons (or supplemental characters) are commonly added to the end of UPC/EAN bar
Symbologies5-16 Magellan® 1000iAdd-ons — continuedSTART / ENDPROGRAMMING BARCODESDisable Optional 2-Digit Add-onsDEFAULTEnable Optional 2-Digit Add-on
GS1 DataBar Omnidirectional / Stacked OmnidirectionalProduct Reference Guide 5-17GS1 DataBar Omnidirectional / Stacked Omni
Symbologies5-18 Magellan® 1000iGS1 DataBar Omnidirectional / Stacked Omnidirectional — continuedMinimum ReadsThis feature specifies the minimum number
GS1 DataBar Expanded / Expanded StackedProduct Reference Guide 5-19GS1 DataBar Expanded / Expanded StackedThe following opt
Symbologies5-20 Magellan® 1000iGS1 DataBar Expanded / Expanded Stacked — continuedLength ControlFixed Length Decoding— When fixed length decoding is e
GS1 DataBar Expanded / Expanded StackedProduct Reference Guide 5-21GS1 DataBar Expanded / Expanded Stacked — continuedGS1 D
Symbologies5-22 Magellan® 1000iGS1 DataBar Expanded / Expanded Stacked — continuedMinimum ReadsThis feature specifies the minimum number of consecutiv
GS1 DataBar Expanded / Expanded StackedProduct Reference Guide 5-23GS1 DataBar Expanded / Expanded Stacked — continuedCoupo